We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for EMI Test System.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

EMI Test System×マイクロニクス - List of Manufacturers, Suppliers, Companies and Products

EMI Test System Product List

1~8 item / All 8 items

Displayed results

[Application Case] Introduction of MR2300 User Case

Japan Cash Machine Co., Ltd., which manufactures currency processing equipment and other related products.

At Japan Cash Machine Co., Ltd. (JCM), we manufacture and sell currency processing equipment, financial-related devices, cash registers, and gaming-related equipment. Our currency processing machines are used in over 110 currencies worldwide, and we hold a dominant market share in the North American and European gaming markets. We have cleared all the stringent regulations specific to the industry and obtained numerous licenses. JCM has become synonymous with casino banknote validators and leverages its local support capabilities to thrive in the global market. The MR2300 EMI testing system is chosen by leading companies in this industry. For more details, please contact us or refer to our catalog.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

EMC Technology <How to Use Simple Measuring Instruments Effectively>

Technical Data: Simple EMI Test System "EMI Total Test System MR2300"

■Conducted EMI Test System MR2150 A pre-compliance system for conducted EMI (noise terminal voltage) testing. By using this system for debugging evaluation before the official EMC testing at a certified site, development costs can be significantly reduced. ■EMI Total Test System MR2300 Ideal for preliminary compliance testing of official EMI tests, known as "Pre-compliance." This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. ■EMS Test System MR2350 A pre-compliance EMS test system for radiated immunity testing (IEC/EN61000-4-3). *For more details, please refer to the PDF document or feel free to contact us.

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Report on the Compatibility of Measurement Data in an Anechoic Chamber

[Technical Data] EMI Test System MR2300/RF Shielded Room MY5410

■EMI Test System MR2300 Ideal for preliminary compliance testing "Pre-compliance" for official EMI tests. This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. ■Anechoic Chamber / Shielded Box MY5410 An anechoic chamber optimal for large-scale EMI testing. It comes standard with a turntable with a diameter of 756mm and a load capacity of 100kg for large EUTs. *For more details, please refer to the PDF materials or feel free to contact us. The MR2300/MY5410 has been developed for pre-compliance use. This enables the measurement of harmonics from switching power supplies in the 40-100MHz range, which was previously difficult. Below are the measurement results obtained with the MR2300/MY5410, compared with results from a 10m anechoic chamber equipped with equivalent facilities using the 3m method.

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Comparison of MR2300 and radiation noise measurement in an anechoic chamber.

[Technical Data] EMI Test System MR2300/RF Shielded Room MY5410

■EMI Testing System MR2300 Ideal for preliminary compliance testing of official EMI tests, known as "Pre-compliance." This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. ■Anechoic Chamber MY5410 An anechoic chamber optimal for large-scale EMI testing. It comes standard with a turntable with a diameter of 756mm and a load capacity of 100kg, suitable for large EUTs. *For more details, please refer to the PDF materials or feel free to contact us. We measured the noise emitted by the CNE (Comparative Noise Emitter), which is widely used for the calibration of anechoic chambers, using the MR2300 and the anechoic chamber, and compared the results.

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Application Case] MR2300 User Case Introduction 2

[Application Example] The MR2300 EMI testing system is used for various products.

This time, we will introduce the case of Company Z, which is engaged in the development, manufacturing, sales, and import/export of electronic musical instruments. (The company name is withheld at their request.) Currently, advanced circuit technology has been introduced into electronic devices for music, and EMI evaluation is required in various fields. 【Product Introduction】 ■ MR2300 EMI Test System *For more details, please refer to the PDF materials or feel free to contact us.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Comparison of MR2300 and radiation noise measurement in an anechoic chamber.

[Technical Data] EMI Test System MR2300 / Anechoic Chamber MY5410MY5410

■EMI Test System MR2300 Ideal for preliminary compliance testing "Pre-compliance" for official EMI testing. This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. ■Anechoic Chamber / Shielded Box MY5410 An anechoic chamber optimal for large-scale EMI testing. It comes standard with a turntable with a diameter of 756mm and a load capacity of 100kg for large EUTs. *For more details, please refer to the PDF materials or feel free to contact us. We measured the noise emitted by the CNE (Comparative Noise Emitter), which is widely used for the calibration of anechoic chambers, using the MR2300 and the anechoic chamber, and conducted a comparison of the results.

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

The relationship between the noise level at the lower limit of measurable radiated EMI and antenna gain.

In radiation EMI measurements, using antennas with high gain allows for the measurement of lower levels of noise.

■Conducted EMI Test System MR2150 A pre-compliance system for conducted EMI (noise terminal voltage) testing. By using this system for debugging evaluation before conducting the official tests at a certified EMC site, significant reductions in development costs can be achieved. By using a high-gain antenna, lower levels of noise can be measured in radiated EMI (emission) measurements.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Report on the Compatibility of Measurement Data in an Anechoic Chamber

[Technical Data] EMI Test System MR2300/RF Shielded Room MY5410

■EMI Test System MR2300 Ideal for preliminary compliance testing of official EMI tests, known as "Pre-compliance." This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. ■Anechoic Chamber MY5410 An anechoic chamber optimal for large-scale EMI testing. It comes standard with a turntable with a diameter of 756mm and a load capacity of 100kg, designed for large EUTs. *For more details, please refer to the PDF materials or feel free to contact us. The MR2300/MY5410 has been developed for pre-compliance use. This enables the measurement of harmonics from switching power supplies in the 40-100MHz range, which was previously difficult. Below are the measurement results obtained with the MR2300/MY5410, compared with measurements conducted in a 10m anechoic chamber equipped with facilities equivalent to the official site, using the 3m method.

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration